A minimally invasive surgical procedure involving the insertion of a device (such as an Amplatzer Vascular Plug II) into a blood vessel to block abnormal blood flow, such as a portosystemic shunt. / 一种微创手术程序,涉及将装置(如Amplatzer血管塞II型)插入血管以阻断异常血流,如门体分流。

Knowledge type
工艺技术
First proposed or discovered
Proposer
Turkey Farm member
Creator
农场主
Last updated
2026-11-14 19:05:32
Login to save this node.

Sub-knowledge points

Cross-sectional vascular mappingTemporary balloon occlusion assessmentAdjunctive gelfoam embolisation of collateral channels

Higher-order knowledge points

Congenital extrahepatic portosystemic shuntsHepatopulmonary SyndromeSuperior Mesenteric Vein (SMV)–Inferior Vena Cava (IVC) communication

Main parameters and performance indicators

Device: Amplatzer Vascular Plug II (12 mm)Adjunct: Gelfoam embolisationPortal Pressure: 7 to 17 mmHg (during temporary balloon occlusion)